Industrial water plant — piping and equipment
Water Technology Engineering

The system that makes water safe at the source.

From drinking water to pools and industrial plants, Skytech Water installs and commissions the E.C.A. system, which makes disinfectant where it is used. From salt, water and electricity: hypochlorous acid at the anode, sodium hydroxide at the cathode.

or call: +90 850 308 26 00

FIG. 01 Industrial water plant
InputSalt · Water · Electricity
Redox1200 mV
Contact time5 – 15 seconds
StorageNo hazardous chemicals
01

Technology

At the core of our systems is electrochemical activation (ECA): using only salt, water and electricity, it produces the required disinfectant where and when it is needed.

Hazardous chemical transport and storage are eliminated. What the cell produces is not a single compound but an oxidant mixture dominated by hypochlorous acid; with a redox potential of 1200 mV it acts far faster than chlorine gas or hypochlorite, yet stays safe for people, animals and equipment at working concentrations.

Technology in detail

1200 mV

Redox potential. Destroys microorganisms not only chemically but by breaking the cell wall with current.

5 – 15 s

Contact time. 80–85% of disinfection completes in this window; chlorine needs 25–30 minutes.

Multi-oxidant

Not a single compound: hypochlorous acid dominant, with chlorine dioxide and peroxide components.

No resistance

Because the active components are meta-stable, no bacterium or virus develops lasting resistance.

FIG. 02 E.C.A. production flow
02

E.C.A. system

E.C.A. system: water and salt inputs on the left, HOCl and NaOH outlet tanks on the right
FIG. 03 E.C.A. system: inputs and two outputs
One system, two products

The E.C.A. system uses a diaphragm electrochemical reactor to make hypochlorous acid at your facility from salt, water and electricity.

The anode yields HOCl for disinfection; the cathode yields sodium hydroxide (caustic) that can be used on site. The diaphragm keeps the two apart. The system is sized to the facility, installed and monitored remotely.

Explore E.C.A. systems

Anode (+) · HOCl

Hypochlorous acid-dominant oxidant. Main product: disinfection.

Cathode (−) · NaOH

Sodium hydroxide (caustic). Second product: alkaline cleaning and pH correction.

04

Our projects

FIG. 01 Race venue and canal
Balıkesir · August 2024

Balıkesir Avlu

Canal water disinfection ahead of a triathlon

Ahead of the triathlon held at Avlu, Balıkesir in August 2024, a Skytech Water system was used to clean and disinfect the canal water. Following five days of work before the race, the canal hosted the event’s swim leg.

View the project →
05

How we work

1

Water analysis & survey

Every project begins with raw-water analysis. Flow rate, water chemistry and target quality values are reported.

2

System design

System configuration, capacity and dosing scenarios are engineered from the analysis results.

3

Installation & commissioning

The system is installed on site and handed over with performance testing.

4

Monitoring & service

Every commissioned system is placed under a periodic maintenance and remote-monitoring protocol.

Let's talk about your project.

Reach us with your water-analysis report and facility details; our technical team will assess the appropriate system configuration.